# A Study on the Coffee Spilling Phenomenon in the Low Impulse Regime

> An annotated edition of this paper on Fermat's Library, where scientists and readers explain its ideas, equations and history in the margins. Annotated edition: https://fermatslibrary.com/s/a-study-on-the-coffee-spilling-phenomenon-in-the-low-impulse-regime

- **Authors:** Jiwon Han
- **Published:** 2016
- **Topic:** Physics
- **Original:** https://s3-us-west-1.amazonaws.com/fermatslibrary/uploads%2F1706461658070-nqj1jvdyg9-a24d8bfedd4522244066f8d7af77db0a%2F1511.0009v1.pdf
- **Pages:** 11
- **Annotations:** 9 comments in 9 threads
- **Featured:** Fermat's Library Journal Club
- **Annotated edition:** https://fermatslibrary.com/s/a-study-on-the-coffee-spilling-phenomenon-in-the-low-impulse-regime

## Annotations

### Annotation 1 (page 1)

Beside the passage: “each liquid container. According to common sense, since the amount of coﬀee is the same inside each cup, the amount of coﬀee that spills from the oscillation should be fairly similar as well. However, this is not the case. As it is clearly shown in Fig 3b, the coﬀee motion inside the wine glass is aggressive while …”

**Annotation** by Luís Batalha (2024-01-28):

> Jiwon Han is currently a 5th year PhD student in Astronomy & Astrophysics at Harvard University, working with Prof. Charlie Conroy and Lars Hernquist. His research interests recently have centered on understanding how an ancient major merger shaped the stellar halo and dark matter halo of our Galaxy, leading to the warping of the galactic disk.
>
> ![](https://jiwonjessehan.github.io/images/profile.png)

### Annotation 2 (page 1)

Beside the passage: “Jiwon Han Korean Minjok Leadership Academy, Gangwon-do, Rep. Korea”

**Annotation** by Luís Batalha (2024-01-28):

> ## TL;DR
>
> The paper focuses on understanding why coffee spills when we walk. It explores the dynamics of liquid oscillation in a mug and how it relates to the motion of the hand and body. The study identifies the resonance frequency of coffee oscillation and investigates methods to suppress this resonance to prevent spilling. This includes analyzing different ways of holding the cup and the effect of adding a foam layer.

### Annotation 3 (page 1)

Beside the passage: “each liquid container. According to common sense, since the amount of coﬀee is the same inside each cup, the amount of coﬀee that spills from the oscillation should be fairly similar as well. However, this is not the case. As it is clearly shown in Fig 3b, the coﬀee motion inside the wine glass is aggressive while …”

**Annotation** by Luís Batalha (2024-01-28):

> Actually, two Ig Nobel Prizes have honored to research that analyzed why coffee might spill when we walk.
>
> The first prize was awarded to in 2012 to [Rouslan Krechetnikov and Hans Mayer](https://improbable.com/ig/winners/#ig2012) and the second one in 2017 to [Jiwon Han for this paper](https://improbable.com/ig/winners/#ig2017).

### Annotation 4 (page 1)

Beside the passage: “Rarely do we manage to carry coﬀee around without spilling it once [Fig 1]. In fact, due to the very commonness of the phenomenon, we tend to dismiss questioning it beyond simply exclaiming: “Jenkins! You have too much coﬀee in your cup!””

**Annotation** by Luís Batalha (2024-01-28):

> Here's a [great video](https://www.youtube.com/watch?v=WGwU_e3uHBc) summarizing this phenomenon and the work on this paper.

### Annotation 5 (page 2)

Beside the passage: “In order to determine the resonance conditions, the ﬁrst and foremost information that must be acquired is the resonance frequency of the oscillator. Here, the oscillator is coﬀee. From the assumption that our liquid in consideration is incompressible, irrotational, and inviscid, the following equation predicts the …”

**Annotation** by Luís Batalha (2024-01-28):

> In 2012, Mayer and Krechetnikov also delved into the coffee spilling problem. Their experimental setup consisted of using a MATLAB-based image analysis tool, and the exact moment when the coffee spilled was pinpointed using a sensor-activated light-emitting diode (LED) signal that kept track of the liquid's level in the mug. Their research concluded that the spilling is influenced by the specific design of standard coffee cups, the physical properties of coffee, and the mechanics involved in the act of walking.
>
> The following image illustrates the process of defining and obtaining the measurements and positional data of the cup used in the coffee spillage studies: (a) the route taken during walking as seen from a top-down perspective, (b) the horizontal coordinates of the cup (x, y) alongside the tilting angle theta and the gravitational pull g, (c) the angle of the spill alpha and the related acceleration x, and (d) the image analysis conducted via MATLAB (Mayer and Krechetnikov, 2012).
>
> ![](https://i.imgur.com/LgUQ2wX.png)

### Annotation 6 (page 3)

Beside the passage: “After investigating the oscillator properties, the next step is to analyze the driving force: the cup. The cup is synchronized with our hand’s motion, which is directly inﬂuenced by our bodily movements. Such body-hand coordination properties have been extensively researched in biomechanical studies [[9], [10], [11], …”

**Annotation** by Luís Batalha (2024-01-28):

> Jiwon, also gave a great Ted talk on this topic, which you can watch [here](https://www.youtube.com/watch?v=4Cd5TxBjdq0)

### Annotation 7 (page 6)

Beside the passage: “Figure 8: The “claw-hand” method of carrying coﬀee.”

**Annotation** by Luís Batalha (2024-01-28):

> There's actually a device you can use to transport beverages without spilling them called [SpillNot](https://www.thespillnot.com/). It features a non-slip mat situated on a base, which is connected to a handle that is, in turn, secured by a ribbon. When a user transports a beverage with the SpillNot by holding the ribbon, the apparatus can swing with considerable magnitude and can even be twirled completely in both vertical and horizontal orientations, as can be seen in the following video.
>
> ![](https://i.imgur.com/LGz6VAX.gif)
>
> If we simplify the SpillNot's function to that of a pendulum, we describe θ as the angle made with the vertical from the lowest point, from which we can derive the vertical and horizontal components of acceleration.
>
> $$
> a_y=T/m \cos \theta - g \\
> a_x=T/m \sin \theta
> $$
>
> therefore, the angle formed by the pendulum with the vertical confirms
>
> $$
> \tan \theta = \frac{a_x}{g+a_y}
> $$
>
> Conversely, typically, a fluid is unable to withstand a force applied tangentially to its surface. As a result, when a system is subjected to steady acceleration, the fluid's free surface tilts, creating an angle with the horizontal plane. The tangent of this angle is determined by
>
> $$
> \frac{a_x}{g+a_y}
> $$
>
> Considering ax and ay as the horizontal and vertical components of acceleration, respectively, as shown in the following picture, we can integrate this information to understand that in order to prevent spillage, the SpillNot's tilt relative to the vertical must match the liquid's tilt relative to the horizontal. Essentially, if the acceleration is almost perpendicular to the base of the SpillNot, the liquid’s surface will stay nearly parallel to the base. This evaluation is a simplification, omitting certain elements like transient effects, movements of the hand, or the finite dimensions of the SpillNot. Nevertheless, it uncovers a crucial insight: to minimize spillage, the radial acceleration needs to be significantly greater than the tangential acceleration.
>
> ![](https://i.imgur.com/wvwdEGF_d.webp?maxwidth=760&fidelity=grand)

### Annotation 8 (page 7)

Beside the passage: “(a)”

**Annotation** by Luís Batalha (2024-01-28):

> The study of liquid dynamics, particularly in the context of sloshing and oscillation, was also deeply connected to rocket development during the 20th century.
>
> It was crucial for ensuring the stability and safety of rockets, as fuel movement within tanks can significantly impact a rocket's balance and trajectory.

### Annotation 9 (page 10)

Beside the passage: “In this paper, we have researched how the periodic force imposed on the cup during locomotion excites the ﬁrst antisymmetric mode of coﬀee oscillation and results in spilling. In order to do so, we approximate the coﬀeecup system to a forced harmonic oscillator, and determine the resonance frequency of coﬀee. The …”

**Annotation** by Luís Batalha (2024-01-28):

> The research on the dynamics of liquid oscillation, like that conducted by Jiwon Han on this paper, has potential applications in enhancing the safety of trucks carrying liquids.
>
> Understanding how liquid moves and resonates inside a container can inform the design of liquid cargo tanks, enabling them to better counteract the sloshing dynamics that often contribute to vehicular instability. The design of such tanks could be optimized to minimize the risk of the liquid cargo's movement causing the truck to flip, thereby reducing the likelihood of accidents. This could be especially critical for trucks transporting large volumes of liquid over long distances.

## Full text

Extracted from the PDF. [Annotation N] marks where each annotation above sits.

#### Page 1

A Study on the Coﬀee Spilling Phenomenon in the Low Impulse Regime ∗

Jiwon Han Korean Minjok Leadership Academy, Gangwon-do, Rep. Korea [Annotation 2]

(Dated: November 2, 2015)

When a glass of wine is oscillated horizontally at 4Hz, the liquid surface oscillates calmly. But when the same amount of liquid is contained in a cylindrical mug and oscillated under the same conditions, the liquid starts to oscillate aggressively against the container walls and results in signiﬁcant spillage. This is a manifestation of the same principles that also cause coﬀee spillage when we walk. In this study, we experimentally investigate the cup motion and liquid oscillation during locomotion. The frequency spectrum of each motion reveals that the second harmonic mode of the hand motion corresponds to the resonance frequency of the ﬁrst antisymmetric mode of coﬀee oscillation, resulting in maximum spillage. By applying these experimental ﬁndings, a number of methods to suppress resonance are presented. Then, we construct two mechanical models to rationalize our experimental ﬁndings and gain further insight; both models successfully predict actual hand behaviors.

I. INTRODUCTION

Rarely do we manage to carry coﬀee around without spilling it once [Fig 1]. In fact, due to the very commonness of the phenomenon, we tend to dismiss questioning [Annotation 4] it beyond simply exclaiming: “Jenkins! You have too much coﬀee in your cup!”

Figure 1: Rarely do we walk without spilling coﬀee.

However, the coﬀee spilling phenomenon is deceivingly simple [1]. As a counter-intuitive example, prepare two liquid containers with distinct geometrical structures; here, we consider a wine-glass and a normal sized cylindrical mug. Pour the same amount of coﬀee inside each glass (this is to ensure that Jenkins does not have “too much coﬀee” in his cup). Since the human walking motion consists of periodic movements on the plane parallel to the walking direction, we will oscillate each cup at a ﬁxed frequency in order to simulate such oscillatory motion. Using the mechanical device shown in Fig 2a, we impose a horizontal excitation X = X 0 cos(2π × 2t) to

∗ No institutions were involved in this study

each liquid container. According to common sense, since [Annotation 1] [Annotation 3] the amount of coﬀee is the same inside each cup, the amount of coﬀee that spills from the oscillation should be fairly similar as well. However, this is not the case. As it is clearly shown in Fig 3b, the coﬀee motion inside the wine glass is aggressive while that of the cylindrical cup is comparatively steady; consequently, the amount of coﬀee spilt is signiﬁcantly diﬀerent. When the driving frequency is changed to 4Hz, we are again surprised. Essentially, the liquid behavior inside each container is completely reversed: while the coﬀee inside the wine glass remains close to equilibrium, the coﬀee inside the cylindrical cup oscillates violently [Fig 3c and Fig 3d]. Although we yet do not have suﬃcient knowledge of the human walking motion, such experiment results are enough to show that the amount of liquid may not be the sole reason behind spilling coﬀee.

(a) (b)

Figure 2: (a) A mechanical setup to maintain a ﬁxed freqeuncy during oscillation. (b) A diagram of the eﬀective

cup height.

Indeed, the spilling of coﬀee is a manifestation of multiple interactions, ranging from the body-hand coordination to the resonance properties of the cup-coﬀee interaction. Thus, in order to gain clearer insight, the coffee spilling phenomenon is divided into two regimes: the low impulse regime and the high impulse regime. The term “impulse” indicates the maximum magnitude of the impulse that the cup experiences. Not surprisingly, the physical properties of each regime are signiﬁcantly dis-

#### Page 2

2

(a) (b)

(c) (d)

Figure 3: Oscillations at (a), (b) 2Hz and (c), (d) 4Hz.

tinct. In the low impulse regime, the interaction between the cup and coﬀee is considered as a periodic function; thus, the oscillation properties are researched extensively. However, in the high impulse regime, the interaction between the cup and coﬀee is momentary and aggressive. Oscillation properties carry less importance in such a regime. Spilling from casual walking falls under the former regime; spilling after tripping on a stone falls under the latter. In the present paper, the low impulse regime is set to be the main focus of study.

Also, the eﬀective cup height (which is deﬁned to be the height of the cup subtracted by the liquid equilibrium level [Fig 2b]) is not considered as a variable in this study for two reasons. First, the role of the eﬀective height of the cup in spilling is rather straight forward. If the eﬀective height of the cup is large enough, the coﬀee is unlikely to spill unless it is ﬂipped over. On the other hand, if the eﬀective height of the cup is close to zero, that is, if the cup is ﬁlled to its brim, the liquid is much more likely to spill. Thus, the taller the cup and lesser the coﬀee, the less you spill. Such a relationship is not investigated to further extent in this study [2]. Second, as much as it is simple, the role of eﬀective cup height is also absolute; thus, it should be considered more as a classiﬁcation than a variable. Again, such an extra classiﬁcation is not included in this study, for it will complicate the research more than deepen our understanding of the phenomenon.

Thus, in this paper, we study the conditions that maximize the amplitude of coﬀee oscillation under the low impulse regime. In the Experiment Studies section, the liquid oscillation properties and the cup’s motion prop-

erties are investigated. Here, a surprising feature of the cup (hand) movement during walking is observed from its frequency spectrum. Then, combining the results from each investigation, it will be revealed how the interplay between the cup and coﬀee leads to spilling. By applying this knowledge, a number of methods to reduce coﬀee spilling are presented as well. Next, in the Model Studies section, two mechanical models of the “normal hand” posture and the “claw-hand” posture are proposed. They are each the oscillating-pivot single pendulum and the oscillating-pivot double pendulum; both models are constructed upon the bold assumption that coﬀee, at least in this study, can be treated as a simple pendulum. Surprisingly, simulation studies reveal that both models successfully predict the important physical properties discovered through experiment. We then conclude the paper with a summary of our discoveries.

II. EXPERIMENT STUDIES

From experience, we know that our carrying hand is usually strong enough to be essentially unaﬀected by the coﬀee’s impact on the cup. This subtle insight can immensely simplify the situation: instead of analyzing both directions of inﬂuence, we can limit ourselves to one. Therefore, it is physically sound to interpret the coﬀeecup system as a forced oscillator. The driving force, which is synchronized with the carrying hand’s motion, is directly exerted on the liquid from the inner walls of the cup. Since we are in the low impulse regime, this driving force is considered periodic; if the driving frequency corresponds to the resonance frequency of coﬀee, the sloshing amplitude reaches its maximum and results in spilling. Thus, the question that we must investigate is clear: what are the resonance conditions of this forced oscillator?

A. Liquid Oscillation Properties

In order to determine the resonance conditions, the ﬁrst and foremost information that must be acquired is the resonance frequency of the oscillator. Here, the oscillator is coﬀee. From the assumption that our liquid in consideration is incompressible, irrotational, and inviscid, the following equation predicts the natural frequen- [Annotation 5] cies of the various modes of ﬂuid oscillation in an upright cylindrical container [[3], [4]].

ω 2 mn = g mn R

tanh(  mn H R

)[1 + σ ρg

(  mn R

) 2 ] (1)

Of the various modes of oscillation, our main interest is the ﬁrst antisymmetric mode. This is because of two reasons: the ﬁrst antisymmetric mode involves the largest amount of liquid mass movement, and as we will see in the following section, its frequency corresponds to the

#### Page 3

3

driving frequency (at least partially). Thus, by substituting the parameters in equation 1 with the generic cup dimensions [5] of 82mm diameter and 95mm height, the generic σ and ρ values for coﬀee [6], and  11 = 1.841, we calculate the ﬁrst antisymmetric mode frequency to be approximately 3.95Hz. Indeed, this value is dependent on the speciﬁc dimensions of the cup, and it is helpful to have a sense of how much the natural frequency would change according to the radius of the cup. Such a relationship is illustrated in Fig 4. Interestingly, the equation predicts a diﬀerent amount of change in the natural frequency when the radius is either increased or decreased: an increase in the radius will not cause the natural frequency to change as much as it would if it were decreased.

Figure 4: The natural frequencies as the radius changes.

The ﬁst antisymmetric mode can also easily be observed in the lab. Using the same mechanical device that was utilized in the introduction, we give the cylindrical cup a short “pump” and record its subsequent surface waves. It is important to make sure that the given impulse is at a reasonable magnitude; if the impulse is too large, unnecessary eﬀects such as the liquid surface breaking or other modes of oscillation being excited will be observed as well. Here, the amplitude of the mechanical vibrator was set to be 2cm and the frequency was ﬁxed at 2Hz, which are reasonable values that correspond to actual dimensions of locomotion. By using the color difference between the coﬀee and the background, we track one point on the liquid surface and plot its height relative to the equilibrium level. The ﬁnal graph is presented in Fig 5a. Visually, the damping oscillation seems to be monochromatic with an exponentially decreasing envelope. The former observation can be easily veriﬁed from the frequency spectrum [Fig 5b], which reveals that the damping oscillation indeed has a single dominant frequency of approximately 3.8Hz. This value is slightly below the predicted frequency of 3.95Hz, most likely due to the viscosity of coﬀee and other unconsidered frictional forces that arise from the cup-coﬀee interactions [7]. The second speculation is a bit trickier. The decreasing envelope is directly related to the damping coeﬃcient γ; however, without suﬃcient knowledge of the input energy and the rate of dissipation, the damping coeﬃcient deﬁned as the following deﬁnition cannot be accurately

(a)

(b)

Figure 5: (a) The relative height of a point on the liquid surface while it oscillates. (b) A FFT analysis of (a) reveals

that the oscillation is fairly close to 3.8Hz.

calculated [8].

γ =

˙ < E l > 2E (2)

Instead, γ is determined by using an exponential curveﬁt of the enveloped curve of the damping oscillation. The damping coeﬃcient is revealed to be approximately 0.674 rad/s, with r-square value of 0.9774. A parameter that can greatly increase this value is discussed in the Suppressing Resonance section.

B. Cup Motion Properties

After investigating the oscillator properties, the next [Annotation 6] step is to analyze the driving force: the cup. The cup is synchronized with our hand’s motion, which is directly inﬂuenced by our bodily movements. Such body-hand coordination properties have been extensively researched in biomechanical studies [[9], [10], [11], [12]], and it is revealed that the hand’s swaying motion during locomotion is dictated by our lower body’s “up and down” movements (H. Pontzer and Lieberman [9] coin the term “passive mass damper” for our hand’s swaying motion). However, we need to be cautious of the fact that the speciﬁc mechanism of the hand’s control of the cup may

#### Page 4

4

change according to how we hold the cup. While such deviations will be investigated in the Suppressing Resonance section and the Model Studies section, for now, we stick to the so-called “normal hand” posture, as illustrated in Fig 6a.

In this research, two methods were employed in order to measure the acceleration of the cup during locomotion. The ﬁrst method, which turned out to be unsuccessful, was to utilize image processing tools. The idea was to track the center of mass of the cup while the cup holder casually walked. That way, it would be possible to extract the time plot of the cup’s position, and subsequently, the time plot of the acceleration of the cup (by taking a second order derivative of the position data). However, this method was unsuccessful due to two main reasons. First, the image data was not sensitive enough. If the data is obtained over a long distance, one would inevitably have to zoom-out; this directly reduces the number of pixels by which the position data is recorded, and results in an extremely “smoothed-out” data plot. On the other hand, if we zoom in as much as we want to, the data collection time span is greatly limited. Unfortunately, we are stuck in a Heisenberg uncertainty principle-like situation in which we cannot achieve both measurements with desired quality at the same time. Second, the visual data was limited to only one plane of oscillation. Although the plane parallel to the walking direction is indeed where most of the action occurs, it would be better if data from all three planes of oscillation could be acquired as well. Such issues were solved by adopting the second method: utilizing an accelerometer [13].

The second method proved to be quite successful. The apparatus, as shown in Fig 6a, is straightforward. By ﬁxing an accelerometer (or, equivalently, a smartphone) to the top of the mug, we record all three directions of acceleration. Since the mug is a hard body, we expect the acceleration measured on any part of the mug to be equal; the accelerometer was also strapped to the bottom of the mug in order to verify that the experiment results were indeed independent of the position of the accelerometer [14].

Representative acceleration plots in each orientation and their respective FFT analysis results are presented in Fig 6b and Fig 6c. Here, the y-axis is the walking direction, the z-axis is the direction perpendicular to the ground, and the x-axis is the remaining sideways direction. From the acceleration time plot, the diﬀerence in the maximum magnitude of acceleration in each axis is highlighted. The z-axis acceleration has the biggest magnitude, and the x-axis acceleration is almost negligible in magnitude compared to the other two. This matches our expectations, since the up-and-down motion of walking is visually much larger than that of sideways swaying. According to the results of H. Pontzer and Lieberman [9], the frequency of the z-axis oscillation should be synchronized with our lower-body movements. Another interesting observation can be made from the frequency

spectrum in each axis. In the acceleration time plot, the z-axis oscillation seems to have a smaller frequency than the y-axis oscillation; this is counter-intuitive, since we expect the cup motion to be have the same frequency as our body (up-and-down oscillation) itself. In order to shine a light on such observation, a FFT analysis is conducted on each acceleration plot.

Indeed, the FFT results are quite enlightening. Let us ﬁrst take note of the y-axis frequency spectrum [Fig 6c]. Evidently, the cup does not oscillate at the same frequency of our body. In fact, the motion is not even close to being purely sinusoidal: at least ﬁve or more distinct harmonic frequencies are contained in the motion. This directly goes against the daily assumption that our hand simply goes up and down when we walk. Instead, the cup-carrying hand undergoes a complex oscillation that is less than perfectly synchronized with our bodily motions. We should note that such intricate oscillations do not stem from the arm itself, but rather the extra degree of freedom that the wrist allows in the cup motion. Another signiﬁcant observation is made by examining the speciﬁc values of the frequency components in the y-axis oscillation. Among the distinct harmonic frequencies, the second harmonic frequency coincides with 3.5 4Hz, which is the resonance frequency of coﬀee in regular sized [5] cylindrical cups. In other words, as we casually walk, our hand oscillates in such a way that resonates with the ﬁrst antisymmetric mode of coﬀee oscillation; thus, the likelihood of coﬀee spilling is maximized. It is important to realize that resonance would not likely occur if higher-frequency modes did not exist in our hand motion. For example, would one still spill coﬀee if the cup was strapped around one’s waist? The answer is probably “no”, since, as we saw in the introduction, coﬀee does not spill as much when it is simply driven at 2Hz. Again, the particularity of the cup motion that allows higher-frequency oscillation is highlighted.

Now we shift our focus to the other two results [Fig 6c]. First, the z-axis oscillation clearly exhibits a dominant frequency close to 1.7Hz. There also exist higher frequencies, but they are rather insigniﬁcant compared to the dominant frequency. This is reﬂected in our experience that the walking motion is largely composed of up-and-down motions, and that the frequency of such up-and-down motion is what we normally perceive to be the walking frequency. Although it cannot initiate a signiﬁcant level of coﬀee sloshing, the z-axis oscillation at 1.7Hz can still amplify the ﬁrst antisymmetric mode in two ways. First, since 1.7Hz is close to half of the resonance frequency, the z-axis oscillation can increase the amplitude of the coﬀee once every two cycles after the ﬁrst antisymmetric mode is excited by y-axis oscillations. Second, there is the possibility of subharmonic resonance, as in the parametrically driven pendulum [[15], [16]]. However, such behavior was neither experimentally nor mathematically investigated thoroughly in this research. Next, it is notable that the x-axis oscillation has a dominant frequency of approximately 1Hz, which

#### Page 5

5

(a)

(b)

(c)

Figure 6: (a) A simple apparatus to measure the acceleration that the cup experiences during locomotion. The acceleration data is recorded on the phone, which is stably ﬁxed on the cup. In order to ensure that the weight of the cup did not change too much, the total weight of the apparatus was set to be equal to that of a 2/3 full cup. (b)

The acceleration time plot in each orientation of measurement. There is a clear periodic tendency. (c) The FFT result in each orientation of measurement. The y-axis oscillation clearly exhibits harmonic frequencies; the second harmonic frequency coincides with the resonant frequency of coﬀee. Due to our up-and-down motion during walking, the

z-axis oscillation exhibits strong periodicity of 2Hz; this is

our normal perceived frequency of walking.

is the half of the walking frequency itself. This reﬂects the sideways swaying motion of our hands when we walk,

which, evidently, occurs once every two walking cycles. The x-axis oscillation, combined with y-axis oscillation, can cause the liquid to circulate around inside the cup.

C. Suppressing Resonance

So far, we have succeeded in uncovering the basic mechanism behind coﬀee spilling: resonance. By investigating the frequency properties of the coﬀee and cup motion, it is now evident that walking excites the ﬁrst antisymmetric mode of coﬀee oscillation. It was also realized that such excitation is enabled by the biomechanical particularity of the cup (hand) motion. Now we ask the practical question. How do we stop spilling? The suggested solution is rather straight forward. Since the culprit behind spilling is resonance, preventing resonance would be suﬃcient to signiﬁcantly reduce the probability of spilling. This can be achieved by altering either the coﬀee’s resonance frequency or the cup motion itself. A number of possible methods to implement such changes are discussed here.

The ﬁrst suggested method is to change the way we walk. By walking backwards, we are able to signiﬁcantly change the frequency characteristics of our hand motion. Using the same experiment setup shown in Fig 6a, we conduct a FFT analysis of the cup’s acceleration when we walk backwards. A representative result is shown in Fig 7. A notable change in the y-oscillation frequency spec-

Figure 7: Frequency spectrum of backwards-walking.

trum is highlighted. Compared to normal walking, the frequency spectrum is more evenly distributed, and the presence of higher frequency modes is greatly reduced; in fact, there does not seem to be a dominant frequency at all. Evidently, the resonance frequency of coﬀee is no longer a signiﬁcant component in the frequency spectrum of the cup. As a result, the ﬁrst antisymmetric mode now has a lesser chance of being excited, leading to a subsequent decrease in the probability of spilling coffee. Perhaps this is due to the fact that we are not used to walking backwards: since we are not accustomed to backwards walking, our motion in the walking direction

#### Page 6

6

becomes irregular, and our body starts to heavily rely on sideways swinging motion in order to keep balance. This accounts for the subtle changes in the x-axis and z-axis frequency spectra as well. Of course, walking backwards may be less of a practical method to prevent spilling coffee than a mere physical speculation. A few trials will soon reveal that walking backwards, much more than suppressing resonance, drastically increases the chances of tripping on a stone or crashing into a passing by colleague who may also be walking backwards (this would most deﬁnitely lead to coﬀee spilling).

Figure 8: The “claw-hand” method of carrying coﬀee. [Annotation 7]

Figure 9: Frequency spectrum of the claw-hand posture.

Fortunately, the second suggested method is a bit more realistic. By changing the way we hold the cup, it is also possible to suppress resonance; the proposed method of cup-holding is illustrated in Fig 13b, and it is named as the “claw-hand” posture. As it will be explained further in the Model Studies section, such a method of holding the cup is mechanically equivalent to adding another oscillatory component to our system. Again, the same mechanical device used in former experiments is used to record the acceleration that the cup undergoes in the claw-hand posture. Then, we investigate changes in the frequency spectrum of the recorded data. A representative FFT analysis result is given in Fig 19. The change in the y-oscillation frequency spectrum is similar to that

of walking backwards: the higher frequency harmonic modes have been reduced greatly, although the dominant frequency near 1.7Hz remains signiﬁcant. Thus, we expect the claw-hand posture to have similar eﬀects on the coﬀee oscillation as walking backwards.

We also propose the method of adding a foam layer to the liquid surface. Such a method was extensively researched by Sauret, Boulogne, Cappello, Dressaire, and Stone [8]. Their study demonstrates that a relatively thin layer of foam can be eﬀective in damping liquid sloshing. A similar but simpliﬁed experiment is conducted in this study. The experiment apparatus illustrated in Fig 10a is used to observe the surface oscillations when a layer of foam was added—a Hele-Shaw cell is used due to the technical diﬃculties of analyzing the surface oscillation in a 3-dimensional container. Three samples are analyzed: the no-foam sample, 1cm foam sample, and the 2cm foam sample. The foaming solution is composed of 90% water and 10% glycerol, and the experiments are performed over a short timespan (about 1 second) so that the decay of the foam layer would be negligible. Again, using the color diﬀerence between the coﬀee and the background, we track one point on the liquid surface. The time plot of the relative height in each sample is presented in Fig 10b. From the frequency spectra in Fig 11a, we observe that the damping frequency decreases from approximately 3.3Hz to 3Hz [17]. Then, from the ﬁtted curve [Fig 11b] of the no-foam sample 1cm foam sample, we note that damping coeﬃcient nearly triples in its value (from 1.025rad/s to 2.928rad/s); according to A. Sauret and Stone [8], this is a result of the energy dissipation in the wall boundary layer.

There is also the method of changing the cup’s resonance property itself. In Fig 4, it is evident that a decrease in the radius of the cup can signiﬁcantly increase the resonance frequency; by dividing the cup into smaller cylindrical cells, as shown in Fig 12, the liquid oscillation is suﬃciently displaced from the resonance domain. However, such an eﬀect is not quantiﬁed in this research [18].

III. MODEL STUDIES

Although a full biomechanical description of the coﬀee spilling phenomenon is beyond the scope of this study, a simpliﬁed mechanical model is proposed and analyzed in order to gain further insight into the dynamics of the phenomenon. So far, we have examined two distinct ways of carrying coﬀee: the “normal hand” posture and the “claw-hand” posture. From the experiment ﬁndings in the previous sections, we now know that the two postures have distinct physical properties; thus, for each posture, a mechanical model that encompasses such diﬀerences is constructed and compared to experiment ﬁndings. The proposed mechanical models are illustrated in Fig 13a and Fig 13b. In both models, the coﬀee’s impact on the cup motion is no longer negligible. Also, for simplicity’s

#### Page 7

7

(a) [Annotation 8]

(b)

Figure 10: (a) A mechanical device to observe the eﬀect of adding foam. Due to technical diﬃculties, a Hele-Shaw cell is used instead of a cylindrical container. (b) The time plot of the relative height in each sample. A drastic decrease in

the amplitude as a foam layer added can be observed.

sake, the walking frequency is set to be 2Hz and the ﬁrst antisymmetric mode is set to be 4Hz (the actual values are approximately 1.7Hz and 3.8Hz). For the normal hand posture, the arm is depicted by a simple harmonic oscillator of mass M. Since the arm itself is not ﬂexible, it is considered to oscillate at 2Hz, perfectly synchronized with the bodily oscillations. Thus, M and the spring constant k are decided so that the natural frequency of M under a small displacement would equal 2Hz. Next, the coﬀee is depicted by a simple pendulum; the simple pendulum oscillating at f corresponds to coﬀee being driven at an external driving force of frequency f. Here, l 1 is decided so that the natural frequency of the simple pendulum would equal that of the ﬁrst antisymmetric mode, which is 4Hz.

Indeed, at ﬁrst, this does not seem to be a physically sound analogy. However, as illustrated in Fig 14, the ﬁrst antisymmetric mode of liquid oscillation somewhat resembles the simple pendulum in the sense that the center of mass oscillates with respect to a ﬁxed point above the liquid surface. Also, as it will be revealed below, the implications of this analogy is astonishingly consistent with experiment results. The claw-hand model is similarly constructed as well. The only modiﬁcation for the

(a)

(b)

Figure 11: (a) The frequency spectra of the no-foam sample (top) and the 1cm-foam sample (bottom). A shift in the dominant frequency to the left can be observed. (b) The ﬁtted curves are plotted with the original data plots. When

1cm of foam layer was added, the damping coeﬃcient γ increased to 2.93rad/s from 2.23rad/s and the angular frequency ω d decreased to 19.83rad/s from 20.16rad/s. The R 2 value for each curve ﬁt is 0.8877(no foam) and

0.7668(1cm foam).

claw-hand model is that the simple pendulum is now a double-pendulum; the claw-hand posture essentially adds one more degree of freedom to the generalized coﬀee-cup coordinate system. Seemingly subtle, this extra degree of freedom will later on prove itself to have a signiﬁcant effect on the frequency spectrum of the cup motion. In the following two subsections, the Euler-Lagrange equations for each mechanical model is solved and investigated extensively.

A. Normal Hand Posture: Oscillating-pivot Simple Pendulum

The generalized coordinate system for the oscillatingpivot simple pendulum and their relevant parameters can

#### Page 8

8

Figure 12: By dividing the cup into smaller cylindrical

cells, we can displace the oscillation from resonance.

(a) (b)

Figure 13: Two mechanical models are proposed. (a) is the “normal hand” posture and (b) is the “claw-hand” posture.

be expressed as te following.



q 1 q 2



=



x θ 1





   

M m 1 l1 k g



   

=



   

1kg 0.1kg 1.55cm 157.9137N/m

9.81m/s 2



   

Next, the system’s kinetic energy, potential energy, and the Lagrangian are calculated to be the following equations.

L normal = T − V (3)

T = M ˙x 2

2 + m 1 2



˙x 2 + (l 1 ˙ θ 1 ) 2 + 2 ˙x ˙ θ 1 l 1 cos(θ 1 )



V = −m 1 gl 1 cos(θ 1 ) + kx 2

2

The corresponding Euler-Lagrange equations are integrated by the Runge-Kutta method, with initial values set to be



x, θ 1



=



2cm, 0.1rad



and timespan

Figure 14: A depiction of the ﬁrst antisymmetric mode and a simple pendulum. The colored circles represent the

center of mass of liquid.

Figure 15: Phase diagrams for the normal hand model.

t = [0s, 60s]. The representative phase diagrams are illustrated in Fig 15.

The arm, represented by x, clearly follows a monochromatic cycle. On the other hand, the coﬀee, represented by θ 1 , follows a more complex trajectory. In order to determine the frequency characteristics of each oscillator (the arm and coﬀee), a FFT analysis is conducted again on each data set. The result is illustrated in Fig 16. The

Figure 16: FFT analysis of the normal hand model. The frequency spectrum of each generalized coordinate x, θ 1 is shown from top to bottom. The timespan is 60s.

upper graph is the frequency spectrum of x and the lower

#### Page 9

9

Figure 17: FFT analysis of the normal hand model. The frequency spectrum of each generalized coordinate x, θ 1 is shown from top to bottom. The timespan is 500s.

graph is the frequency spectrum of θ 1 . Indeed, the arm oscillates monochromatically at 2Hz as our body would during actual walking. What is surprising is the result for θ 1 . Just as we have discovered in our former experiments, the coﬀee is excited at 4Hz, even though the arm itself oscillates at 2Hz. Although a deﬁnitive conclusion cannot be made without further biomechanical insight, our model suggests that such particularities of the cup motion may indeed be a result of the “extra degree of freedom” that the wrist provides. Also, our model shows that the characteristics of walking can be simulated in well-deﬁned dynamical systems such as this one.

Another interesting observation can be made when the timespan is greatly extended. For example, the frequency spectra of x and m 1 are illustrated in Fig 17 when the timespan is extended to 500s.

A conspicuous shift in the frequency spectrum has occurred: the high frequency component (4Hz) of m 1 has disappeared and a low frequency component (1 1.5Hz) has newly appeared. In other words, as the time elapsed, the system evolved into a stable state in which only low frequency oscillations remained. This may be a potential answer to the thought-provoking question: “if one were to walk for an inﬁnite amount of time, would coﬀee be inevitably spilt at some point?” If we only considered the fact that our hand motion resonates with coﬀee, the answer appears to be “yes”. However, as our model suggests, if our hand motion evolves into an oscillation state that does not resonate with coﬀee, the answer may certainly be “no”. Of course, since we usually do not walk for 500 seconds or more with a cup of coﬀee, such stabilization hardly ever takes place; our mechanical model merely suggests the possibility of it.

B. Claw-hand Posture: Oscillating-pivot Double Pendulum

The generalized coordinate system for the oscillatingpivot double pendulum and their relevant parameters can

be expressed as the following.





q 1 q 2 q 3



 =





x θ 1 θ 2







       

M m 1 m 2 l1 l2 k g



       

=



       

1kg 0.1kg 0.1kg 15cm 1.55cm 157.9137N/m

9.81m/s 2



       

Now, there is an extra m 2 and l 2 term involved. Consequently, the system’s kinetic energy, potential energy, and the Lagrangian take a more complex form than the oscillating-pivot simple pendulum.

L clawhand = T − V (4)

T = M 2 ˙x 2 + m 1 2



˙x 2 + (l 1 ˙ θ 1 ) 2 + 2 ˙x ˙ θ 1 l 1 cos(θ 1 )



+ m 2 2



˙x 2 + (l 1 ˙ θ 1 ) 2 + (l 2 ˙ θ 2 ) 2 + 2l 1 l 2 ˙ θ 1 ˙ θ 2 cos(θ 1 + θ 2 )



+ m 2 ˙x



l 1 ˙ θ 1 cos(θ 1 ) + l 2 ˙ θ 2 cos(θ 2 )



V = kx 2

2

− m 1 g



x + l 1 cos(θ 1 )



− m 2 g



x + l 1 cos(θ 1 ) + l 2 cos(θ 2 )



Again, the corresponding Euler-Lagrange equations are integrated by the Runge-Kutta method. The initial values are set to be



x, θ 1 , θ 2



=



2cm, 0.1rad, 0.1rad



and timespan t = [0s, 60s]. The representative phase diagrams are illustrated in Fig 18. Compared to the clawhand model, a visual diﬀerence in the phase diagram for coﬀee (represented by θ 1 in Fig 15 and θ 2 in Fig18) is evident. Such a diﬀerence can quantiﬁed through a FFT analysis of the claw-hand model, as shown in Fig 19.

Figure 18: Phase diagrams for the claw-hand model.

#### Page 10

10

Figure 19: FFT analysis of the claw-hand model. The frequency spectrum of each generalized coordinate x, θ 1 , θ 2 is shown from top to bottom. The timespan is 60s.

As expected, mass M oscillates at a frequency close to 2Hz. Although the motion is not as purely sinusoidal as the normal-hand model, it is still fairly monochromatic. But as we shift our focus to the next two frequency spectra, a notable deviation from that of the normal hand model is observed. While in the normal hand model, the dominant frequency was increased as we shifted from the main oscillator (M) to the subsequent oscillator (θ 1 ), the case for the claw-hand model is completely the opposite. Starting from approximately 2Hz, the dominant frequency is halved for each subsequent oscillator (θ 1 , θ 2 ). Ultimately, the driving frequency of the cup (θ 2 ) is pronouncedly displaced from the resonance frequency. Although our experiment results for the claw-hand posture suggest a less extreme eﬀect, our model successfully predicts that the claw-hand posture may indeed suppress resonance. The slight deviation from actual experiment results most likely arises from the fact that, in reality, θ 1 and θ 2 cannot oscillate as independently as described by the claw-hand model; the actual claw-hand posture should be an in-between state of the normal hand model and the claw-hand model.

Figure 20: A comparison of the angular acceleration that θ 1 in the normal hand model(blue) and θ 2 in the claw-hand model(red) undergoes.

Additionally, the diﬀerence in the magnitude of the coﬀee’s acceleration in each mechanical model is compared in Fig 20. Even though the amplitude of the M oscillation is similar, as can be seen in Fig 21, the conse-

Figure 21: A comparison of the ampitude of oscillation

that M undergoes in each model. The blue line is the normal hand model and the red line is the claw-hand model.

quent acceleration that the coﬀee oscillator undergoes has a notable diﬀerence in magnitude. Since the magnitude of acceleration is directly proportional to the magnitude of impulse that an oscillator is given in one cycle, we expect such a diﬀerence in magnitude to have signiﬁcant eﬀects on the consequent coﬀee oscillation. Although we are currently under the low impulse regime, it is interesting that such a diﬀerence in the magnitude of impulse can be predicted by our mechanical model. Again, since the magnitude of acceleration in the claw-hand model is signiﬁcantly smaller, the claw-hand posture is less likely to spill coﬀee.

IV. DISCUSSION

In this paper, we have researched how the periodic force imposed on the cup during locomotion excites the ﬁrst antisymmetric mode of coﬀee oscillation and results in spilling. In order to do so, we approximate the coﬀee- [Annotation 9] cup system to a forced harmonic oscillator, and determine the resonance frequency of coﬀee. The damping coeﬃcient is additionally measured in order to show that the damping frequency ω d and the resonance frequency ω r have almost the same value. Then, using a simple mechanical apparatus, we record the acceleration of the cup during locomotion and analyze its frequency spectrum to show that the walking direction acceleration contains harmonic modes of higher frequency than the “up-anddown” walking motion. Among these harmonic modes, the second lowest frequency mode corresponds to the resonance frequency of coﬀee; thus, we verify that the ﬁrst antisymmetric mode of coﬀee is indeed stimulated during walking motion. Moreover, we show that either walking backwards or holding the cup with the “claw-hand” posture can lead to a signiﬁcant change in the frequency spectrum of the cup motion, suggesting that resonance can be suppressed through such methods. The eﬀect of adding a foam layer in a Hele-Shaw cell is also examined; we show that the damping frequency decreases and the damping coeﬃcient increases signiﬁcantly when a foam layer is added (extensive studies on the foam layer is done

#### Page 11

11

by A. Sauret and Stone [8]).

Next, in order to rationalize the experiment results and to gain further insight, we construct two mechanical models of the normal hand posture and the claw-hand posture. In both models, phase diagrams reveal a clear periodicity in the base oscillator (M, which corresponds to the arm) but a more complex cycle for the endmost oscillators (θ 1 for the normal hand model and θ 2 for the claw-hand model). From the frequency spectrum of each endmost oscillator, we show that the model successfully

demonstrates the physical properties realized in previous experiments: θ 1 in the normal hand model carries a 4Hz component and θ 2 in the claw-hand model oscillates at a frequency lower than 2Hz. Another theoretical ﬁnding was that the endmost oscillator in the normal hand model stabilizes to a lower frequency mode as time elapses— this may perhaps account for the fact that spillage is less likely to occur later on during walking motion. Also, it was predicted that the former oscillator undergoes a signiﬁcantly larger magnitude of acceleration than the latter.

[1] Note1. Coﬀee spilling has been extensively researched by

H. C. Mayer and R. Krechetnikov. However, the experimental approach and the conclusion is quite diﬀerent. T. Kulczycki, M. Kwasnicki, and B. Siudeja have also taken a diﬀerent approach on the subject as well; based on an appropriate Steklov eigenvalue problem, their research puts a focus on the geometrical properties of the ﬂuid. Refer to [4] and [19]. [2] Note2. A statistical correlation between the probability

of spilling and the eﬀective cup height may be an interesting topic for future research. [3] R. A. Ibrahim. Liquid sloshing dynamics: Theory and

applications. Cambridge University Press, 2005. [4] H. C. Mayer and R. Krechetnikov. “Walking with coﬀee:

Why does it spill?” Physical Review E, 85(046117), 2012. doi:10.1103/PhysRevE.85.046117. [5] “Amplifer”. The standard coﬀee mug di-

mensions. URL http://blog.ampli.fi/ the-standard-coffee-mug-dimensions/. [6] Note3. The surface tension of a generic cup of coﬀee has

been researched by V.Sobolik [20] to be approximately 0.037N/m at 40 ◦ C. [7] Note4. Indeed, the actual “natural frequency” should

be derived from the relation ω r =

 ω 2 0 − 2γ 2  1/2 and ω d =

 ω 2 0 − γ 2  1/2 where ω d is 2π × 3.8Hz and ω r is the resonance frequency. However, the damping coeﬃcient is determined to be approximately 0.674rad/s. Considering that ω 2 d is around 570rad 2 /s 2 , the diﬀerence between ω d and ω 0 is negligible. [8] J. Cappello E. Dressaire A. Sauret, F. Boulogne

and H. A. Stone. “Damping of liquid sloshing by foams”. Physics of Fluids, 27(022103), 2015. doi: 10.1063/1.4907048. [9] D. A. Raichlen H. Pontzer, J. H. Holloway and D. E.

Lieberman. “Control and function of arm swing in human walking and running”. The Journal of Experimental Biology, 212, 2009. doi:10.1098/rspb.2009.0664. [10] P. G. Adamczyk S. H. Collins and A. D. Kuo. “Dy-

namic arm swinging in human walking”. Proceedings of the Royal Society B: Biological Sciences, 2009. doi: 10.1098/rspb.2009.0664. [11] Stella F. Donker. “Flexibility of Human Walking: A study

on interlimb coordination”. PhD thesis, 2002. [12] M. G. Pandy F. C. Anderson. “Dynamic Optimization

of Human Walking”. Journal of Biomechanical Engineering, 5(123), 2001. doi:10.1115/1.1392310. [13] Note5. Unfortunately, accelerometers are infamous for

their inaccuracy and high level of noise. However, since we are mostly concerned with information related to frequency, and noise signals are random by deﬁnition, the most essential data extracted from the accelerometer would be fairly reliable. A noise test was conducted in order to conﬁrm that no dominant frequency was shown in a FFT analysis. [14] Note6. There exists the issue that the cup also undergoes

a “nodding” motion as we walk, which would mean that the “x, y, z” orientations recorded by the accelerometer slightly change during motion. And, as we will mention later, such an extra degree of freedom is what allows the cup’s intricate oscillation. However, the magnitude of the nodding motion itself is much smaller in scale compared to the other orientations of oscillation. Thus, we ignore the changes in the axis during locomotion. [15] Eugene Butikov. “Subharmonic Resonances of the Para-

metrically Driven Pendulum”. Journal of Physics A: Mathematical and General, 35, 2002. [16] Joseph Rudnick. “Subharmonics and the Transition to

Chaos”, Lecture Notes in Physics. Springer, 1969. [17] Note7. The deviation from the values in Fig 5a is due

to the distinct geometries of the Hele-Shaw cell and a cylindrical cup. [18] Note8. The cleaning of such a cup would indeed be quite

a tedious job. [19] M. Kwasnicki T. Kulczycki and B. Siudeja. “Spilling

from a Cognac Glass”. 2013. URL http://arxiv.org/ abs/1311.7296. [20] M.Delgado R.Zitny K.Allaf V.Sobolik, V.Tovcigrecko.

“Viscosity and electrical conductivity of concentrated solutions of soluble coﬀee”.

---

Source: [Fermat's Library](https://fermatslibrary.com/) — https://fermatslibrary.com/s/a-study-on-the-coffee-spilling-phenomenon-in-the-low-impulse-regime. More annotated papers: https://fermatslibrary.com/llms.txt